Air Tightness Testing for Energy Storage Battery Cabinets: How to Choose the CTS C28 Vacuum Decay Leak Detector

PLUS (Guangzhou) Intelligent Technology Co., Ltd. | CTS Sentinel C28WE pressure decay / vacuum decay leak detector · 100% in-line inspection for Energy Storage Battery Cabinet Sealing Test · 32 test programs · ambient drift correction · traceable data
energy storage battery cabinet sealing test energy storage cabinet air tightness test vacuum decay leak detector CTS C28 energy storage enclosure leak test battery cabinet sealing

One-sentence answer: Energy storage battery cabinets are exposed to outdoor and coastal environments over the long term. Once a weld seam, explosion-proof valve or liquid cooling connector develops a micro-leak, moisture and salt spray ingress will cause insulation degradation and busbar corrosion. Using the CTS Sentinel C28WE (C28) leak detector to perform vacuum decay or pressure decay overall leak testing on the cabinet cavity is a common solution on energy storage PACK production lines.

01

I. Industry pain points: three difficulties specific to energy storage cabinets

1Compounded outdoor corrosive environment.

Cabinets mostly serve in coastal and industrial park environments. Under the long-term action of moisture and salt spray introduced by micro-leaks, corrosion spreads from the busbar to the cell terminals, and often only becomes apparent months after commissioning.

2Many plugging ports, fixture leaks easily mixed in.

Coolant inlet/outlet ports, explosion-proof valves, BMS connectors and lifting holes all coexist. The more plugging points there are, the higher the probability that a fixture's own leak is misjudged as a product leak.

3Slow pressure equalization in large-volume cavities.

The internal volume is large, so after inflation or evacuation, airflow and temperature equalization takes time; insufficient stabilization will cause the judgment value to drift.

02

II. Test object and failure risks

Sealing pointsMain failure surfaces and leakage consequences

Sealing locations: upper cover seal strip compression surface, wall panel weld seams and stitch-welded corners, cold plate through-hole seals, explosion-proof valve and breather valve, BMS connector panel gasket.Consequences of leakage: decreased insulation resistance inside the cabinet, busbar corrosion, accelerated oxidation of metal parts in salt spray environments; in severe cases, insulation alarms are triggered, the entire cabinet is taken off the line for rework, and the cost of on-site replacement far exceeds the cost of interception on the production line.

03

III. Test solution: why choose the CTS C28

C28 solutionHow pressure decay / vacuum decay testing covers this part

  • Dual methods adapt to different cabinet states: For cabinets not yet loaded with internal components, pressure decay inflation testing can be used; for fully assembled cabinets, vacuum decay can be used to evacuate from the outside, avoiding internal pressurization.
  • Resistance to ambient drift: Built-in ambient drift correction algorithm and absolute pressure sensor suppress temperature and atmospheric pressure fluctuations, suitable for long-cycle testing.
  • Long-term consistent criteria: Leak rate resolution 0.0005 scc/min (a resolution specification, not equal to the minimum leak rate the instrument can detect); the built-in calibrated leak supports automatic calibration and self-test, suitable for long-cycle comparison of large cabinets.
  • Production line integration: Single-channel compact wall-mount, 32 test programs cover different capacity cabinet types; RS232 / Ethernet / EtherNet/IP together with digital I/O complete sorting/rejecting, and results can be uploaded to MES.
04

IV. Test process and key points

ProcessFrom plugging and evacuation or charging to sorting and data retention

  1. 1Recall the program according to the cabinet type, and use the fixture to plug the coolant ports, explosion-proof valve and connectors.
  2. 2Evacuate or inflate → stabilization → detection → judgment. For large-volume cabinets, priority should be given to ensuring sufficient stabilization.
  3. 3Digital I/O drives cylinders and alarm lights for sorting/rejecting, and results are archived and uploaded by serial number.
  4. 4Perform automatic calibration and self-test with the built-in calibrated leak every shift; when switching cabinet types, only recall the program.
Key points: Fixing the plugging method and stabilization time, and separately verifying fixture leaks and product leaks, is the key to controlling misjudgment.Higher pressure is not always better. Energy storage cabinets have large volumes and thin wall panels; excessive inflation pressure will cause elastic expansion of the cabinet, and during the stabilization stage this deformation continuously absorbs pressure, so the true leak signal is drowned out by the deformation effect; the pressure must also match the cabinet's designed pressure-bearing capacity to avoid irreversible deformation caused by the test itself. The stabilization window must likewise be relaxed according to volume and ambient temperature: the larger the volume and the more pronounced the workshop temperature difference, the longer it takes for pressure and temperature to reach equilibrium.
05

V. FAQ

Q1Should an energy storage battery cabinet be tested by inflation or evacuation?

According to the process agreement. If internal pressurization is allowed and contamination-free testing is pursued, use pressure decay; if the direction of external moisture ingress needs to be simulated, use vacuum decay. The C28WE supports both methods and can switch between them by program on the same instrument.

Q2The cabinet is large and the test time is long. How can environmental interference be reduced?

First ensure reliable plugging and sufficient stabilization, then rely on ambient drift correction and the absolute pressure sensor to offset temperature and atmospheric pressure fluctuations. The C28's built-in correction algorithm is designed precisely for long-cycle, large-volume testing.

Q3Is there a standard basis for cabinet air tightness inspection?

Protection ratings usually reference the provisions on IP ratings in IEC 60529 / GB/T 4208, and enterprises define air tightness limits accordingly. The acceptance criteria should be clearly stated in the technical agreement; the instrument is responsible for stable judgment according to the program.

Q4Will the explosion-proof valve and breather structure on the cabinet be misjudged as a leak?

Yes, unless separate criteria are defined for them. The explosion-proof valve and breather valve themselves have a controlled ventilation rate, which appears as a slow and stable pressure change during evacuation or pressurization, different from the continuously declining curve shape of a real leak. Independent parameters should be set for such channels in the program, or they should be temporarily plugged according to process regulations; if they share one limit with the body, a normally breathing cabinet will be judged as defective.

06

VI. Conclusion

The key to air tightness of energy storage battery cabinets is reliable plugging, resistance to ambient drift, and traceability. The CTS C28WE, with its dual direct pressure/vacuum decay methods and 32 programs, adapts to mixed-line production of multiple cabinet types, and together with custom plugging fixtures forms a stable defense line for energy storage PACK sealing quality.

07

PLUS — CTS C28 Pressure Decay / Vacuum Decay Leak Detector and Sealing Test Solutions

PLUS (Guangzhou) Intelligent Technology Co., Ltd. was founded in 2018 and specializes in sealing and leak testing. It is a National High-Tech Enterprise (Certificate No.: GR202244005066) and has passed ISO 9001 quality management system certification. The company integrates technology development, production and sales, delivering high-precision air tightness testing solutions for new energy drive systems, energy storage, automotive components, consumer electronics and communication equipment — including leak detector selection, custom plugging fixtures, production line integration, installation and commissioning, and personnel training.
Why the C28: the CTS Sentinel C28WE supports both pressure decay (direct pressure) and vacuum decay in one instrument, and also performs blockage testing. A built-in absolute pressure sensor with ambient drift correction removes the effect of workshop atmospheric pressure swings on long test cycles. Leak rate resolution is 0.0005 scc/min (a resolution figure), with a built-in calibrated leak for automatic calibration and self-test — well suited to large-volume parts and full inspection of complete assemblies.

CTS Sentinel C28WE Pressure / Vacuum Decay Leak Detector

  • Pressure decay and vacuum decay in one unit, plus blockage testing
  • Absolute pressure sensor with ambient drift correction
  • 0.0005 scc/min leak rate resolution, built-in calibrated leak for auto calibration
  • Compact single-channel wall-mount with 32 storable test programs
  • RS232 / Ethernet / EtherNet-IP for MES integration

CTS I28 Multi-Function Single-Station Model

  • Runs several test stages in sequence in one instrument
  • For "cavity first, then sub-cavity" test strategies
  • Results stored by serial number and uploadable to MES

CTS A28 Differential Pressure Model (optional)

  • Master part and part under test pressurized together, differential pressure read directly
  • Preferred for thin-walled and plastic parts where temperature gradients are large
  • Pairs with the C28 for two-level component plus assembly testing

Plugging Fixtures and Line Integration

  • Custom-formed plugging fixtures built to the connector or contour
  • Production line integration, installation, commissioning and training
  • Equipment maintenance and instrument calibration (in-house PLUS capability)
08

Contact Us

Official Website
www.plusgz.com
Service Hotline
400 999 0513
Business Email
info@plusgz.com
Address
3rd Floor, Building A1, No. 36 Xinhe North Road, Zengcheng National Development Zone, Guangzhou, China
Contact Phone
13660225670
Company Qualifications
High-Tech Enterprise / Technology-Based SME / ISO 9001
Note: the technical parameters in this article are subject to CTS official datasheets and product manuals. The actual delivered configuration is subject to the technical agreement of the order.
Copyright © 2026 PLUS (Guangzhou) Intelligent Technology Co., Ltd. All rights reserved. 粤ICP备2023022749号