Application of the CTS A28 Differential Pressure Leak Detector in Sealing Tests for Gas Proportional Valves

PLUS (Guangzhou) Intelligent Technology Co., Ltd. | CTS Sentinel A28 differential pressure leak detector · 100% in-line inspection for Gas Proportional Valve Sealing Test · master-part comparison · 32 test programs · traceable data
gas proportional valve sealing test gas valve air tightness test differential pressure leak detector CTS A28 gas leakage detection diaphragm and valve seat sealing

One-sentence answer: A gas proportional valve handles gas on/off control, proportional regulation, and electrical control at the same time. Sand holes in the valve body, poor contact between the diaphragm and the valve seat, and failure of the isolation between the gas chamber and the electrical chamber can all cause gas leakage or abnormal combustion. Using the CTS Sentinel A28 differential pressure leak detector to compare a master part with the part under test allows micro-leaks to be identified at low pressure, making it suitable for 100% inspection of every piece on gas appliance component production lines.

01

I. Industry pain points: the safety boundary for gas components is the strictest

1The consequences of leakage are irreversible, and the tolerance for misjudgment is the lowest.

Gas leakage can cause deflagration and carbon monoxide poisoning. Therefore, the purpose of testing gas proportional valves is not to screen for process defects but to intercept safety issues. Any practice that increases the judgment margin must be premised on not missing a rejection.

2Valve bodies are mostly castings or die castings, with sand holes and shrinkage cavities randomly distributed.

Internal casting defects may only become through-going after machining. Micropores along the gas passage are invisible to the naked eye and can only be exposed by pressure testing.

3The contact state between the diaphragm and the valve seat depends on assembly precision.

Proportional valves rely on the fit among the diaphragm, valve core, and valve seat to achieve pressure stabilization and regulation. Diaphragm wrinkles, foreign matter indentations, or spring preload deviations can all form leakage paths.

4The gas passage must be completely isolated from the electrical control chamber.

Once the chamber containing the coil, position sensor, and control circuit communicates with the gas chamber, dust and moisture will corrode the electrical components. This is a structural safety design issue.

02

II. Test object and failure risks

Sealing pointsMain failure surfaces and leakage consequences

Sealing locations:

  • The mating sealing face among the valve seat, valve core, and diaphragm (determines closed-valve leak rate);
  • The wall thickness of the valve body casting itself and each machined hole (casting micropores forming through-channels);
  • The isolation wall and lead sealing between the gas chamber and the electrical control chamber;
  • The sealing faces of port threads and the mounting flange.

Consequences of leakage: In the closed-valve state, gas continuously seeps out and accumulates in the kitchen or equipment compartment, and may deflagrate upon contact with an ignition source. Long-term micro gas leakage can also cause excessive carbon monoxide and personnel poisoning. If the isolation wall fails, electrical components corrode and fail, and the valve fails when it needs to actuate. This is a safety-related failure mode.

03

III. Test solution: why choose the CTS A28

A28 solutionHow differential pressure comparison solves this testing challenge

Gas proportional valves are workpieces with small volume, high-reliability judgment requirements, and batch production:

  • Differential pressure comparison structure: Based on direct pressure, the A28 adds a differential pressure decay circuit and a differential pressure sensor. The master part and the part under test are pressurized simultaneously, and the differential pressure between them is read directly. Ambient temperature fluctuations act on both workpieces in approximately the same way and cancel each other out in the differential pressure channel, so micro-leaks at low pressure can still be distinguished stably.
  • Low-pressure safety testing: The criterion comes from the relative differential pressure between the two workpieces, so there is no need to increase charging pressure in exchange for sensitivity. This helps set the test pressure within the product's permitted safety range.
  • Multiple test programs and calibration: The A28 is a single-channel wall-mounted model and can store 32 test programs. Different test items such as closed-valve leakage and isolation between the gas chamber and electrical chamber can each have their own test program. It has a built-in leak standard and supports automatic calibration and self-test, and calibration records can be retained.

If the same station also needs to handle flow-type testing in the open-valve state, or if multiple test methods need to be connected in series within the same instrument, the multifunctional single-station model I28 can be selected.

04

IV. Test process and key points

ProcessFrom plugging and stabilization to sorting and data retention

  1. 1Plugging: Use custom-formed fixtures to plug the gas inlet and outlet and the electrical interface. The flange face should be designed with a pressing surface according to the shape of the sealing face.
  2. 2Charging and stabilization: Charge the cavity under test with dry air or nitrogen, and wait for pressure stabilization according to the test program.
  3. 3Testing: Enter the differential pressure test stage, use dry compressed air as the medium, and judge separately according to the two channels of closed-valve leakage and chamber isolation.
  4. 4Judgment and sorting/rejecting: The instrument completes sorting/rejecting through digital I/O. Defective valve bodies are isolated and reviewed by quality inspection, and do not flow into final assembly.
  5. 5Data retention: Results are stored by valve body serial number and uploaded to MES for traceability by the final assembly plant.
Key points: The test medium must be dry air or nitrogen, and actual gas must not be used. The testing area should remain ventilated. The master part must be rechecked periodically with the built-in leak standard to ensure a reliable judgment baseline.
05

V. FAQ

Q1Can gas proportional valves be directly tested for air tightness using gas?

Gas cannot be used for testing. Production line air tightness testing uses dry air or nitrogen, which both avoids the accumulation of combustible gas at the testing station and facilitates unified calibration of the instrument and fixture. Gas-related combustion performance and emission verification belong to the scope of complete machine bench testing and are divided differently from 100% inspection on the production line.

Q2Should closed-valve leakage and open-valve characteristics be tested separately?

Yes, they should be separated. Closed-valve leakage determines whether there is seepage when the valve is closed and directly corresponds to safety risk. Open-valve characteristics involve flow and regulation ratio and belong to performance verification. Use the A28 to create separate test programs for the two types of items. Safety items undergo 100% inspection piece by piece, while performance items are executed according to the specified sampling inspection plan.

Q3How can it be ensured that micro-leaks are not missed?

Three conditions must be met at the same time: use differential pressure comparison to reduce the interference of temperature drift on readings, use a stable master part as the comparison reference, and perform automatic calibration and self-test on the instrument periodically with the built-in leak standard. Only by incorporating these three things into daily checks and test programs can the judgment of micro-leaks be repeatable.

06

VI. Conclusion

Sealing testing of gas proportional valves is essentially safety item interception, with the lowest tolerance for misjudgment. The CTS Sentinel A28 uses differential pressure comparison to stably distinguish micro-leaks at low pressure. Combined with custom-formed fixtures, 32 test programs, and built-in leak standard calibration, it meets the requirements for 100% inspection of every piece and traceability on gas appliance component production lines.

07

PLUS — CTS A28 Differential Pressure Leak Detector and Sealing Test Solutions

PLUS (Guangzhou) Intelligent Technology Co., Ltd. was founded in 2018 and specializes in sealing and leak testing. It is a National High-Tech Enterprise (Certificate No.: GR202244005066) and has passed ISO 9001 quality management system certification. The company integrates technology development, production and sales, delivering high-precision air tightness testing solutions for new energy drive systems, automotive components, home appliances and general industry — including leak detector selection, custom plugging fixtures, production line integration, installation and commissioning, and personnel training.
Why differential pressure: the CTS Sentinel A28 pressurizes a master part and the part under test at the same time and reads the differential pressure between them directly. Ambient temperature drift affects both parts in nearly the same way and cancels out in the differential pressure channel, so readings are more stable than single-channel direct pressure — ideal for thin-walled parts, plastic parts and larger cavities.

CTS Sentinel A28 Differential Pressure Leak Detector

  • Differential pressure comparison, reads the difference between master part and part under test
  • Single-channel wall-mounted model with 32 storable test programs
  • Built-in calibrated leak, supports automatic calibration and self-test
  • Digital I/O drives fixture cylinders and stack light for accept/reject sorting

CTS I28 Multi-Function Single-Station Model

  • Combines several test methods in one instrument
  • Suited to large-volume cavities and multi-process testing
  • Results stored by serial number and uploadable to MES

CTS C28 Vacuum Decay / Direct Pressure Model

  • Single-part, single-method vacuum decay or pressure decay testing
  • Standard choice where ambient temperature is stable and parts are consistent
  • Complete, traceable daily check and calibration records

Plugging Fixtures and Line Integration

  • Custom-formed plugging fixtures built to the connector or contour
  • Production line integration, installation, commissioning and training
  • Equipment maintenance and instrument calibration (in-house PLUS capability)
08

Contact Us

Official Website
www.plusgz.com
Service Hotline
400 999 0513
Business Email
info@plusgz.com
Address
3rd Floor, Building A1, No. 36 Xinhe North Road, Zengcheng National Development Zone, Guangzhou, China