Air Tightness Testing for 400G Optical Module Housings: CTS C28 Leak Detector Applications and Key Points

PLUS (Guangzhou) Intelligent Technology Co., Ltd. | CTS Sentinel C28WE pressure decay / vacuum decay leak detector · 100% in-line inspection for Optical Module Housing Sealing Test · 32 test programs · ambient drift correction · traceable data
optical module housing sealing test optical module air tightness test vacuum decay leak detector CTS C28 400G optical module sealing optical component leak test

One-sentence answer: 400G optical modules have high power consumption and contain internal optical components. A micro-leak in the housing allows moisture to condense during temperature cycling, causing optical degradation and worsening insertion loss. Using a CTS Sentinel C28WE (C28) leak detector to perform air tightness testing on the module housing via vacuum decay is a viable way to stop condensation risk before shipment.

01

I. Industry Pain Points: Three Difficulties Specific to Optical Module Housings

1A micro-leak is fatal.

The internal optical path of an optical module is extremely sensitive to moisture. Even a very small leak channel repeatedly absorbs and releases moisture under temperature cycling, eventually condensing on the optical surface, which manifests as optical degradation and link instability.

2Housing sealing depends on dispensing and the upper cover.

Die-cast or zinc alloy housings and upper covers are mostly bonded by sealant or compressed seal strips. Variations in adhesive layer thickness and curing quality can create hidden channels.

3Interfaces and pull-tab structures interfere with plugging.

The optical port, pull tab, release latch, and gold finger side all need plugging, and the optical port end face and gold fingers must not be contaminated.

02

II. Test Object and Failure Risks

Sealing pointsMain failure surfaces and leakage consequences

Sealing locations: the sealant or seal strip between the housing and upper cover, sealing around the optical port, openings for the pull tab and release structure, and the breather structure used to balance internal and external pressure.Consequences of leakage: after moisture intrusion, condensation forms on the optical surface, causing increased insertion loss and optical degradation; corrosion of metal parts degrades contact and shielding performance; long-term reliability of the module in data center operation decreases, and maintenance replacement costs are high.

03

III. Test Solution: Why Choose CTS C28

C28 solutionHow pressure decay / vacuum decay testing covers this part

  • Vacuum decay avoids internal pressurization: No pressure is applied inside the module, avoiding additional stress on internal optical components and fiber coupling structures.
  • High criterion resolution: Leak rate resolution 0.0005 scc/min (a resolution specification, not equal to the minimum leak rate the instrument can detect), suitable for consistent judgment of very small leaks.
  • Resistance to ambient drift: Built-in ambient drift correction algorithm and absolute pressure sensor suppress interference from temperature rise and atmospheric pressure fluctuations on readings.
  • Production line integration: Single-channel compact wall-mount design, 32 test programs cover different packages and models; RS232 / Ethernet / EtherNet/IP and digital I/O complete sorting/rejecting and data upload.
04

IV. Test Process and Key Points

ProcessFrom plugging and evacuation or charging to sorting and data retention

  1. 1Call the recipe according to model, use the fixture to plug the optical port, pull tab, and gold finger side. Contact surfaces must not damage the end face or plating.
  2. 2Vacuum pumping → stabilization → testing → judgment. The test pressure differential is determined by the adhesive layer and internal component tolerance.
  3. 3Digital I/O outputs pass/fail signals, and results are archived and uploaded to MES by module serial number.
  4. 4Perform automatic calibration and self-test with the built-in calibrated leak every shift; when the package model changes, only switch the recipe.
Key points: Fixture materials should avoid shedding particles. Optical port plugging components need regular cleaning and replacement to prevent contamination from becoming a new source of failure.Sealing failure in optical modules is cumulative over time, and testing must be understood in the time dimension. Temperature cycling causes gas inside and outside the housing to exchange repeatedly, and micro-leak channels continuously transport moisture over a period of time. Therefore, the criterion should be based on the stable reproducibility of small leak rates, not the absolute value of a single reading. The test pressure differential should also not be too high: the housing and upper cover are mostly bonded by an adhesive layer, and excessive pressure differential itself loads the adhesive layer. Repeated testing is equivalent to continuously consuming sealing margin.
05

V. FAQ

Q1Why are optical module housings so sensitive to micro-leaks?

Because the failure mechanism is repeated moisture absorption and release under temperature cycling. During operation, temperature rise allows moisture to penetrate; during shutdown and cooling, condensation forms on the optical surface. Long-term accumulation causes optical degradation and worsening insertion loss. Therefore, judgment needs to target consistency of very small leaks, not rough threshold-based judgment.

Q2How should the optical port and pull tab be plugged?

Use custom-formed soft rubber plugging components to cover the optical port and pull tab openings, avoiding hard metal contact that can scratch the end face or plating, and ensure the plugging components do not generate particles. The plugging reliability of these locations directly affects the false-judgment rate and should be included in daily checks.

Q3Why prefer vacuum decay instead of direct pressure?

Direct pressure requires pressurizing the inside of the module, which applies additional stress to the internal optical coupling structure; vacuum decay only needs external vacuum pumping to establish a pressure differential and does not introduce contamination risk, making it more suitable for precision parts such as optical modules.

Q4If the housing contains a desiccant, will the test result be affected?

Yes, depending on whether it has already been packaged. The desiccant will release adsorbed moisture under low-pressure conditions, creating additional pressure change; if testing is performed at the finished product stage, this portion is mixed with real leakage, and the reading becomes larger. The safer approach is to complete housing-level air tightness testing before the desiccant is installed, and at the finished product stage only perform confirmatory sampling inspection, while considering the desiccant's outgassing characteristics as a background quantity in the recipe.

06

VI. Conclusion

The core of air tightness testing for 400G optical module housings is to stop micro-leaks, avoid internal pressurization, and keep end faces clean. The CTS C28WE uses vacuum decay, ambient drift correction, and 32 recipes to adapt to multi-package mixed-line testing. Combined with non-shedding plugging fixtures, it forms a front-end safeguard for module reliability.

07

PLUS — CTS C28 Pressure Decay / Vacuum Decay Leak Detector and Sealing Test Solutions

PLUS (Guangzhou) Intelligent Technology Co., Ltd. was founded in 2018 and specializes in sealing and leak testing. It is a National High-Tech Enterprise (Certificate No.: GR202244005066) and has passed ISO 9001 quality management system certification. The company integrates technology development, production and sales, delivering high-precision air tightness testing solutions for new energy drive systems, energy storage, automotive components, consumer electronics and communication equipment — including leak detector selection, custom plugging fixtures, production line integration, installation and commissioning, and personnel training.
Why the C28: the CTS Sentinel C28WE supports both pressure decay (direct pressure) and vacuum decay in one instrument, and also performs blockage testing. A built-in absolute pressure sensor with ambient drift correction removes the effect of workshop atmospheric pressure swings on long test cycles. Leak rate resolution is 0.0005 scc/min (a resolution figure), with a built-in calibrated leak for automatic calibration and self-test — well suited to large-volume parts and full inspection of complete assemblies.

CTS Sentinel C28WE Pressure / Vacuum Decay Leak Detector

  • Pressure decay and vacuum decay in one unit, plus blockage testing
  • Absolute pressure sensor with ambient drift correction
  • 0.0005 scc/min leak rate resolution, built-in calibrated leak for auto calibration
  • Compact single-channel wall-mount with 32 storable test programs
  • RS232 / Ethernet / EtherNet-IP for MES integration

CTS I28 Multi-Function Single-Station Model

  • Runs several test stages in sequence in one instrument
  • For "cavity first, then sub-cavity" test strategies
  • Results stored by serial number and uploadable to MES

CTS A28 Differential Pressure Model (optional)

  • Master part and part under test pressurized together, differential pressure read directly
  • Preferred for thin-walled and plastic parts where temperature gradients are large
  • Pairs with the C28 for two-level component plus assembly testing

Plugging Fixtures and Line Integration

  • Custom-formed plugging fixtures built to the connector or contour
  • Production line integration, installation, commissioning and training
  • Equipment maintenance and instrument calibration (in-house PLUS capability)
08

Contact Us

Official Website
www.plusgz.com
Service Hotline
400 999 0513
Business Email
info@plusgz.com
Address
3rd Floor, Building A1, No. 36 Xinhe North Road, Zengcheng National Development Zone, Guangzhou, China
Contact Phone
13660225670
Company Qualifications
High-Tech Enterprise / Technology-Based SME / ISO 9001
Note: the technical parameters in this article are subject to CTS official datasheets and product manuals. The actual delivered configuration is subject to the technical agreement of the order.
Copyright © 2026 PLUS (Guangzhou) Intelligent Technology Co., Ltd. All rights reserved. 粤ICP备2023022749号