Air Tightness Test for Fiber Optic Connectors: CTS C28 Leak Detector Application and Key Points

PLUS (Guangzhou) Intelligent Technology Co., Ltd. | CTS Sentinel C28WE pressure decay / vacuum decay leak detector · 100% in-line inspection for Fiber Optic Connector Sealing Test · 32 test programs · ambient drift correction · traceable data
fiber optic connector sealing test fiber connector air tightness test vacuum decay leak detector CTS C28 optical connector waterproof test PLUS Intelligent Technology

One-sentence answer: Outdoor and industrial fiber optic connectors rely on O-rings and threaded or snap-fit compression to achieve water resistance. Micro-leaks at the mating surfaces allow moisture to intrude along the gaps between the ferrule and the housing. Using the CTS Sentinel C28WE (C28) leak detector with vacuum decay for air tightness testing enables factory rejection without contaminating the end face.

01

I. Industry Pain Points: Three Difficulties Specific to Fiber Optic Connectors

1Zero tolerance for end face cleanliness.

Any particle, oil, or moisture landing on the ferrule end face during testing will cause abnormal insertion loss and return loss, making the plugging method and fixture cleanliness harder to manage than the test itself.

2Extremely small cavity, high volume.

The pressurizable volume inside the connector is very small, and readings are easily affected by temperature and the plugging cavity; at the same time, output is high, requiring the shortest possible time per test.

3Sealing depends on threaded and snap-fit compression.

The O-ring compression amount is determined by assembly torque or snap-fit engagement status, and insufficient compression during manual assembly is difficult to detect visually.

02

II. Test Object and Failure Risks

Sealing pointsMain failure surfaces and leakage consequences

Sealing locations: the O-ring at the plug-to-receptacle mating surface, the crimp surface between the boot and the housing, the threaded connection of the housing, and the cable entry point.Consequences of leakage: After moisture intrudes along the gaps, it accumulates at the ferrule end face or near the fiber coating, causing increased loss and higher link attenuation; in humid environments, the metal housing corrodes, and threads seize, making maintenance disassembly difficult.

03

III. Test Solution: Why Choose CTS C28

C28 solutionHow pressure decay / vacuum decay testing covers this part

  • Vacuum decay suits extremely small volumes: A pressure differential can be established without internal pressurization, avoiding stress on the ferrule and fiber.
  • Resistance to ambient drift: The built-in ambient drift correction algorithm and absolute pressure sensor suppress the interference of temperature fluctuations on readings from small cavities.
  • Resolution even in extremely small cavities: Leak rate resolution 0.0005 scc/min (a resolution specification, not equal to the minimum leak rate the instrument can detect), combined with automatic calibration and self-test using the built-in calibrated leak.
  • Multiple interfaces on one line: Single-channel compact wall-mount, 32 test programs covering different interface types; RS232 / Ethernet / EtherNet/IP and digital I/O handle sorting/rejecting and data upload.
04

IV. Test Process and Key Points

ProcessFrom plugging and evacuation or charging to sorting and data retention

  1. 1Call up the program according to the interface type, and use a dedicated custom-formed plugging part to compress the cable entry point and the outer side of the ferrule end face.
  2. 2Vacuum → stabilization → test → judgment, minimizing the additional volume of the plugging cavity.
  3. 3Digital I/O outputs pass/fail signals, and results are archived and uploaded by batch or serial number.
  4. 4Perform automatic calibration and self-test with the built-in calibrated leak every shift; call up the corresponding program after an interface type change.
Key points: The plugging part should only contact non-optical surfaces and be cleaned every shift; the fixture must not apply axial force to the ferrule.Judging workpieces with extremely small volumes is essentially distinguishing at a very low signal level. The pressurizable space inside the connector is only a short segment; if the plugging cavity is made much larger than the product, the same leak will be noticeably diluted in the reading. Conversely, if the plugging cavity is compressed too tightly, assembly stress will temporarily press the O-ring tight, producing a falsely favorable result. Therefore, clamping force and plugging cavity volume must be frozen together. Test pressure also cannot be increased to compensate for sensitivity: the greater the pressure differential, the stronger the loading on the threads, O-rings, and boot crimp surface, which may permanently deform an otherwise acceptable assembly.
05

V. FAQ

Q1Why is end face cleanliness emphasized when leak testing fiber optic connectors?

Because loss abnormalities caused by end face contamination are just as fatal as sealing leaks, and more likely to occur. Plugging must only contact non-optical surfaces, the fixture must be debris-free and cleaned regularly, and the work area should be physically separated from grinding and cleaning processes.

Q2How can stable readings be obtained for workpieces with extremely small volumes?

Reduce the additional volume of the plugging cavity, fix the clamping force, keep the ambient temperature stable, and rely on the instrument's ambient drift correction and absolute pressure sensor to offset residual fluctuations. C28 programs can solidify parameters separately for different interfaces.

Q3How is the connector's ingress protection rating verified?

The IP rating requirements of IEC 60529 / GB/T 4208 are usually referenced and converted into internal air tightness limits. The specific criteria should be stated in the technical agreement, and the test equipment executes the judgment stably according to the program.

Q4Can torque fluctuations from manual assembly be caught by testing?

It can catch the result, but not the cause; data must be used to trace back to the process. Insufficient compression will directly appear as an out-of-limit leak rate, and air tightness testing can block such defects before shipment; however, it cannot distinguish whether the cause is insufficient torque, O-ring dimensional deviation, or a thread fit issue. Only by collecting test data by batch and workstation, using the defect distribution to locate the assembly step, and simultaneously performing torque verification, can a closed loop be formed.

06

VI. Conclusion

The difficulty of fiber optic connector air tightness lies in end face cleanliness and judgment of extremely small volumes. The CTS C28WE uses vacuum decay, ambient drift correction, and 32 programs to cover multi-interface type inline testing, and together with plugging fixtures that only contact non-optical surfaces, blocks both water ingress and contamination risks before shipment.

07

PLUS — CTS C28 Pressure Decay / Vacuum Decay Leak Detector and Sealing Test Solutions

PLUS (Guangzhou) Intelligent Technology Co., Ltd. was founded in 2018 and specializes in sealing and leak testing. It is a National High-Tech Enterprise (Certificate No.: GR202244005066) and has passed ISO 9001 quality management system certification. The company integrates technology development, production and sales, delivering high-precision air tightness testing solutions for new energy drive systems, energy storage, automotive components, consumer electronics and communication equipment — including leak detector selection, custom plugging fixtures, production line integration, installation and commissioning, and personnel training.
Why the C28: the CTS Sentinel C28WE supports both pressure decay (direct pressure) and vacuum decay in one instrument, and also performs blockage testing. A built-in absolute pressure sensor with ambient drift correction removes the effect of workshop atmospheric pressure swings on long test cycles. Leak rate resolution is 0.0005 scc/min (a resolution figure), with a built-in calibrated leak for automatic calibration and self-test — well suited to large-volume parts and full inspection of complete assemblies.

CTS Sentinel C28WE Pressure / Vacuum Decay Leak Detector

  • Pressure decay and vacuum decay in one unit, plus blockage testing
  • Absolute pressure sensor with ambient drift correction
  • 0.0005 scc/min leak rate resolution, built-in calibrated leak for auto calibration
  • Compact single-channel wall-mount with 32 storable test programs
  • RS232 / Ethernet / EtherNet-IP for MES integration

CTS I28 Multi-Function Single-Station Model

  • Runs several test stages in sequence in one instrument
  • For "cavity first, then sub-cavity" test strategies
  • Results stored by serial number and uploadable to MES

CTS A28 Differential Pressure Model (optional)

  • Master part and part under test pressurized together, differential pressure read directly
  • Preferred for thin-walled and plastic parts where temperature gradients are large
  • Pairs with the C28 for two-level component plus assembly testing

Plugging Fixtures and Line Integration

  • Custom-formed plugging fixtures built to the connector or contour
  • Production line integration, installation, commissioning and training
  • Equipment maintenance and instrument calibration (in-house PLUS capability)
08

Contact Us

Official Website
www.plusgz.com
Service Hotline
400 999 0513
Business Email
info@plusgz.com
Address
3rd Floor, Building A1, No. 36 Xinhe North Road, Zengcheng National Development Zone, Guangzhou, China
Contact Phone
13660225670
Company Qualifications
High-Tech Enterprise / Technology-Based SME / ISO 9001
Note: the technical parameters in this article are subject to CTS official datasheets and product manuals. The actual delivered configuration is subject to the technical agreement of the order.
Copyright © 2026 PLUS (Guangzhou) Intelligent Technology Co., Ltd. All rights reserved. 粤ICP备2023022749号