Application of CTS I28 in Sealing Tests for Lens Mounts and Connectors

PLUS (Guangzhou) Intelligent Technology Co., Ltd. | CTS Sentinel I28 multi-function leak detector · 100% in-line inspection for Industrial Vision Camera Housing Sealing Test · multiple test methods in one instrument · temperature drift compensation · traceable data
industrial vision camera sealing test industrial camera air tightness test multi-function leak detector CTS I28 lens mount leak test connector sealing test

One-sentence answer: Industrial vision camera housings must protect internal sensors and circuits in dust, cutting fluid and washdown environments. With the CTS Sentinel I28 multi-function leak detector, pressure decay and differential pressure decay tests can be run sequentially (in-series) at the same station to determine the sealing condition of the housing, lens mount and connectors.

Industrial vision camera housing and lens mount
Sealing control for industrial camera housings and lens mounts

Lens mount, connectors and housing joints are the main leak paths; the IP rating decides field reliability

01

I. Industry pain points: three difficulties in industrial camera testing

1The lens mount is both an optical locating surface and a sealing surface.

The fit between the lens mount ring and the housing must ensure both optical axis accuracy and sealing performance; assembly deviation affects imaging and protection at the same time.

2The sealing of the connector seat depends on assembly quality.

Cameras commonly use industrial connectors such as M12; the O-ring between the connector and the housing will partially lose its seal if the assembly direction or torque is incorrect.

3The bonded surface of the window glass is an independent leak path.

Glass and metal or engineering plastics have different coefficients of thermal expansion, and after temperature cycling the bonded surface may develop fine channels.

02

II. Test object and failure risks

Sealing pointsMain failure surfaces and leakage consequences

Sealing locations: front and rear housing parting surface, lens mount-to-housing mating surface, connector seat-to-housing sealing surface, and the bonded or press-fit surface of the window glass.Consequences of leakage: dust and liquid ingress cause abnormal imaging, increased image noise and sensor damage; contamination of the optical cavity causes image defects and calibration drift.

03

III. Test solution: why choose CTS I28

I28 solutionHow sequential multi-method testing covers this part

  • Multiple methods in one instrument: A camera housing contains both a relatively large main cavity and small-volume areas such as the lens mount and connector seat. The I28 offers pressure decay, differential pressure decay and mass flow configurations on the same platform, and supports programming different methods into the same instrument for sequential (in-series) execution, so each area can be judged individually.
  • Clean and flexible deployment: Testing uses dry, oil-free and water-free air supply to avoid oil mist contaminating the optical cavity; the I28 can interface with a PLC, or be used stand-alone for R&D and small-batch verification.

Why multiple methods in series are essential here. The sealing surfaces of the housing are distributed across areas of different natures: the main cavity has a larger volume and is suitable for pressure decay to obtain an overall conclusion; the cavities of the lens mount and connector seat are very small in volume, and pressure readings are sensitive to temperature and clamping disturbances, so direct pressure testing is easily masked by interference. Differential pressure decay is more suitable here, comparing a master part with the test part under similar temperature conditions. The bonded surface between the window glass and the housing is another independent path; glass and metal or engineering plastics have different coefficients of thermal expansion, and after temperature cycling the bonded surface may develop fine channels, which is likewise easily averaged out in an overall air tightness result. By programming the main cavity, lens mount and connector seat as separate segments, each using a matching method and conditions, defects can be traced to a specific sealing surface.

04

IV. Test process and key points

ProcessFrom plugging and pressurizing to sequential testing and data retention

  1. 1Fixturing and plugging: Locate by the housing outline, plug the connector seat and lens interface, and ensure the fixture does not press on the window.
  2. 2Pressurization: Inflate according to the test program; keep the optical cavity dry.
  3. 3Sequential (in-series) testing: First judge the housing parting surface and window area, then judge the small-volume areas of the lens mount and connector seat.
  4. 4Sorting/rejecting: Digital I/O drives sorting/rejecting; abnormal camera housings are isolated for re-inspection.
  5. 5Record retention: Upload results by camera model and serial number.
Key points: Camera-type workpieces are sensitive to cleanliness, so fixtures must be cleaned regularly; perform a self-test with the built-in leak standard before each shift.
05

V. FAQ

Q1Do the sealing and optical accuracy of the lens mount affect each other?

Yes. The lens mount both locates the optical axis and participates in sealing; assembly deviation may affect imaging and protection at the same time. During testing, the lens mount area can be programmed as a separate segment for judgment, making it easier to distinguish whether the problem is assembly-related or seal-related.

Q2How can the M12 connector seat be judged separately?

The cavity of the connector seat is small in volume and is suitable for judgment by a differential pressure decay segment. The I28 runs the housing segment and the connector seat segment in series within the same instrument and records the conclusions separately, making it easy to locate leakage to a specific sealing surface or connector.

Q3Do small batches in the R&D stage also need production line equipment?

The I28 can run stand-alone or interface with a PLC via EtherNet/IP or PROFINET. In the R&D and small-batch verification stage it can be used in stand-alone mode, and once production volume increases it can be connected to the production line control system; deployment is flexible.

Q4Will the optical cavity be contaminated by the test air supply?

Not as long as the air supply and fixtures are controlled. Testing uses a clean, dry, oil-free and water-free air supply, and the piping remains dry, so no oil mist or moisture is left in the optical cavity; fixtures must be cleaned regularly and seals replaced on schedule to prevent residues from entering the cavity with the airflow, so that both optical performance and ingress protection rating are maintained.

06

VI. Conclusion

The difficulty of industrial vision camera housings lies in the dispersed sealing surfaces and the optical cleanliness requirements. The multi-segment sequential (in-series) capability of the CTS Sentinel I28 and its suitability for a clean air supply make it suitable for factory sealing inspection and new product verification of industrial camera housings.

07

PLUS — CTS I28 Multi-Function Leak Detector and Sealing Test Solutions

PLUS (Guangzhou) Intelligent Technology Co., Ltd. was founded in 2018 and specializes in sealing and leak testing. It is a National High-Tech Enterprise (Certificate No.: GR202244005066) and has passed ISO 9001 quality management system certification. The company integrates technology development, production and sales, delivering high-precision air tightness testing solutions for medical devices, robotics, industrial control equipment and smart meters — including leak detector selection, custom plugging fixtures, production line integration, installation and commissioning, and personnel training.
Why the I28: the CTS Sentinel I28 is a multi-function single-station instrument that offers pressure decay, differential pressure decay and mass flow configurations on one platform, and can run different test types in sequence inside the same instrument — one clamping setup completes the full "micro-leak first, then flow patency" sequence, so a blockage is never misread as a leak. Temperature drift compensation can be enabled in the sequence, and EtherNet/IP and PROFINET let it run standalone or talk to a PLC.

CTS Sentinel I28 Multi-Function Leak Detector

  • Pressure decay, differential pressure decay and mass flow configurations
  • Sequential multi-stage testing inside one instrument, one clamping setup
  • Multiple stored test programs for fast changeover
  • Temperature drift compensation for small-volume, temperature-sensitive parts
  • EtherNet/IP and PROFINET, standalone or PLC-integrated

CTS C28 Pressure / Vacuum Decay Model (optional)

  • Pressure decay and vacuum decay in one unit, plus blockage testing
  • Absolute pressure sensor with ambient drift correction for large volumes
  • Compact single-channel wall-mount with 32 test programs

CTS A28 Differential Pressure Model (optional)

  • Master part and part under test pressurized together, differential pressure read directly
  • Preferred for thin-walled and plastic parts with large temperature gradients
  • Combines with the I28 for component-level and assembly-level testing

Plugging Fixtures and Line Integration

  • Custom-formed plugging fixtures with quick changeover
  • Production line integration, installation, commissioning and training
  • Equipment maintenance and instrument calibration (in-house PLUS capability)
08

Contact Us

Official Website
www.plusgz.com
Service Hotline
400 999 0513
Business Email
info@plusgz.com
Address
3rd Floor, Building A1, No. 36 Xinhe North Road, Zengcheng National Development Zone, Guangzhou, China
Contact Phone
13660225670
Company Qualifications
High-Tech Enterprise / Technology-Based SME / ISO 9001
Note: the technical parameters in this article are subject to CTS official datasheets and product manuals. The actual delivered configuration is subject to the technical agreement of the order.
Copyright © 2026 PLUS (Guangzhou) Intelligent Technology Co., Ltd. All rights reserved. 粤ICP备2023022749号